Description
Product overview: Fluke 1662 Multifunction Testers
Fluke 1662 Multifunction Installation Tester delivers solid, basic installation testing features
The Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.
- Measures RCD switching time and tripping level (ramp test)
- Measures trip time and current for RCD type A & AC in one test
- Measures RCD variable current
- Provides automatic RCD test sequence
- Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
- Provides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation
- Includes a phase sequence indicator
- Comes with hard carrying case, padded carrying and waist strap, and remote control probe and lead
Key features
A solid, reliable, basic installation tester
- Tests voltage and frequency
- Checks wiring polarity to detect broken N wires
- Measures insulation resistance and loop and line resistance
- Measures motor windings with continuity test
- Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)
Specifications: Fluke 1662 Multifunction Testers
AC voltage measurement |
||
Range |
500 V |
|
Resolution |
0.1 V |
|
Accuracy 45 Hz – 66 Hz |
0.8% + 3 |
|
Input impedance |
360 kΩ |
|
Overload protection |
660 V rms |
|
Continuity testing (RLO) |
||
Range (autoranging) |
20 Ω / 200 Ω / 2000 Ω |
|
Resolution |
0.01 Ω / 0.1 Ω / 1 Ω |
|
Open Circuit Voltage |
>4 V |
|
Insulation resistance measurement (RISO) |
||
Accuracy of tTest voltage (at rated test current) |
+10%, -0% |
|
Test voltage |
100 V |
|
Insulation resistance range |
20 MΩ / 50 MΩ |
|
Resolution |
0.01 MΩ / 0.1 MΩ |
|
Test current |
1 mA @ 50 kΩ |
|
Loop and line impedance (ZI) |
||
Range |
10 Ω / 0.001 Ω / High current mΩ mode |
|
Resolution |
0.01 Ω / 0.1 Ω / 1 Ω |
|
Prospective earth fault current, PSC test |
||
Range |
1000 A / 10 kA (50 kA) |
|
Resolution |
1 A / 0.1 kA |
|
Computation |
Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. |
|
RCD testing, RCD types tested |
||
RCD Type |
A4, AC¹, G², S³ |
|
Notes |
¹Responds to AC |
|
Tripping speed test (ΔT) |
||
Current settings¹ |
10-30-100-300-500-1000 mA – VAR |
|
Multiplier |
x ½, x 1 |
|
Measurement range |
RCD Type G |
310 ms |
RCD Type S |
510 ms |
|
Notes |
¹1000 mA type AC only |
|
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN) |
||
Current range |
30% to 110% of RCD rated current¹ |
|
Step size |
10% of IΔN² |
|
Dwell time |
Type G |
300 ms/step |
Type S |
500 ms/step |
|
Measurement accuracy |
±5% |
|
Specified trip current ranges (EN 61008-1) |
50% to 100% for Type AC |
|
Notes |
¹30% to 150% for Type A IΔN > 10 mA |
|
Phase Sequence Indication |
||
Icon |
 Phase Sequence indicator is active. |
|
General Specifications |
||
Size (L x W x H) |
10 x 25 x 12.5 cm |
|
Weight (incl. batteries) |
1.3 Kg |
|
Battery size, quantity |
Type AA, 6 ea. |
|
Sealing |
IP-40 |
|
Safety |
Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition |
|
Overvoltage |
CAT III / 500V; CAT IV 300V |
|
Performance |
EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition |
Â
Â